10062 Overflow during Document Check-in

The following problem was Visual Basic related, and was related to a specific customer's custom scripts. It may/may not be applicable to your situation.

Problem:

Customer is getting an error message from the scripting engine that says "10062 Overflow." when trying to check in a document via [[RJS Imaging Scan Workstation]].

Solution:

Checked the PreProcessExit procedure in their custom RJSIMGSCAN.BAS script. They were formatting their customer number as Format(CInt(sReturnVariant(1)), "00000") in order to force it to have a minimum of 5 digits.
 
Changed this line to Format(CLng(sReturnVariant(1)),"00000") and it worked.
 
The problem was that the sReturnVariant(1) was defined as a Long so the size of the numeric being returned was too large to fit in a standard Int, thus causing the overflow problem. Check the variables being passed through the script for datatype mismatch.
Product or Component Name: 
Sort Code: 

Contact Technical Support

Are you an existing RJS customer needing technical help?

Phone

Call Us: 1 (888) 757-7638
Hours: Mon-Fri 8am to 5pm CST

 

Log In To GoToMeeting

To connect to an online meeting, enter the ID provided by the organizer.

 

iForms Upgrade? What a Great Idea!

Looking to upgrade or replace your outdated or unsupported e-forms software? iForms just may be the ticket. Learn More